SIRCAL · GREENSILVER

Argon Purifiers

Argon purifiers and dryers for OES spectrometers. A stable spark, reliable nitrogen and oxygen measurement in steel and fewer repeat analyses.

Argon purifiers and dryers

They are installed in the argon line, directly before the spectrometer, and remove oxygen, nitrogen, moisture and other impurities from the gas. We supply, install and maintain the systems below.

Why argon purity matters

In spark emission spectrometry, argon fills the spark stand and shields the discharge from the air. Even very small amounts of oxygen, nitrogen or moisture in the gas change how the spark behaves:

  • Unstable spark and “white” burns, resulting in poor repeatability and repeat analyses.
  • Wrong nitrogen and oxygen values, because the instrument also “sees” the impurities in the gas, not only the element in the sample.
  • Measurement drift, which means more frequent standardisation with setting-up samples.

Argon from a good supplier can be of high purity, but impurities also enter along the way: when cylinders are changed, from pressure regulators and pipework, or from differences between batches. A purifier directly before the spectrometer ensures constant gas quality regardless.

How an argon purifier works

The gas passes through heated getter materials, such as titanium or zirconium, which chemically bind oxygen and nitrogen. A second stage removes carbon monoxide, hydrogen and hydrocarbons, and a molecular sieve at ambient temperature retains moisture and carbon dioxide. Over time these materials become saturated and their tube is replaced or regenerated according to the manufacturer’s instructions.

SIRCAL

SIRCAL MP-2000 – Argon purifier

The MP-2000 from the British company SIRCAL is a proven argon purification system designed for optical emission spectrometers. Inside a furnace, a titanium tube at high temperature (about 680 °C) retains oxygen and nitrogen, while a copper oxide tube (about 450 °C) removes carbon monoxide, hydrogen and hydrocarbons. An external molecular sieve dryer retains moisture and CO₂ and can be regenerated in situ.

According to the manufacturer, the MP-2000 reduces total impurities to below 1 vpm, for a typical input of 10 vpm, at flow rates of up to 8 litres per minute. The LCD display shows furnace operating hours and faults, and the tubes are easily replaced from the top and front of the unit.

  • Removes: O₂, N₂, H₂, CO, CO₂, H₂O and hydrocarbons
  • Outlet purity: < 1 vpm total impurities
  • Maximum flow: 8 l/min · Maximum inlet pressure: 17 bar
  • Warm-up: less than 15 minutes
  • Dimensions: 642 × 349 × 218 mm (H × W × D) · Weight: 19 kg
  • Self-sealing ¼″ connections (6 mm also available)
GREENSILVER

GREENSILVER Purespark – Argon purifier

The Purespark from the German company GREENSILVER is a stand-alone argon purification unit installed next to the spectrometer. It has two independent furnaces. In the first (450–800 °C), a zirconium and aluminium oxide tube chemically removes oxygen, nitrogen, hydrocarbons, carbon monoxide and hydrogen. A molecular sieve retains moisture and CO₂ and can be regenerated repeatedly.

According to the manufacturer, outlet purity is better than 3 ppm and the purification tubes last about 5 years in continuous operation when the operating instructions are followed. Automatic temperature control with thermocouples, multiple safety alarms and a display showing the temperature of each furnace make operation simple and safe.

  • Removes: O₂, N₂, H₂O, CO, CO₂, H₂ and hydrocarbons
  • Outlet purity: < 3 ppm
  • Maximum flow: 20 l/min · Maximum inlet pressure: 15 bar
  • Warm-up: 25 minutes (furnace 1), 15 minutes (furnace 2)
  • Dimensions: 520 × 460 × 300 mm (H × W × D) · Weight: 28.5 kg · 220 V, 1.2 kW
  • Quick-connect couplings in 316L stainless steel

Accessories: argon valve with quick-connect coupling for easy cylinder changes, double-walled flexible stainless-steel hoses and brass adapters for the gas inlet of any spectrometer.

SIRCAL

SIRCAL PD-2012 – Argon dryer

The PD-2012 is a compact dryer that removes moisture and carbon dioxide from argon using a molecular sieve. It is installed in-line, between the gas supply and the spectrometer, without any special preparation, and can be regenerated in situ.

It is the economical solution when the argon is of good quality and the problem is mainly moisture, for example from cylinder changes or long supply lines. The MP-2000 already includes an equivalent dryer, so the PD-2012 is only needed where there is no complete purifier.

  • Removes: H₂O and CO₂
  • Maximum flow: 10 l/min · Maximum inlet pressure: 17 bar
  • Dimensions: 480 × 200 × 150 mm (H × W × D) · Weight: 3 kg
  • Self-sealing ¼″ connections (6 mm also available)

Comparison

SIRCAL MP-2000GREENSILVER PuresparkSIRCAL PD-2012
TypeComplete purifierComplete purifierDryer
O₂ and N₂YesYesNo
Moisture and CO₂YesYesYes
Outlet purity< 1 vpm< 3 ppm–
Maximum flow8 l/min20 l/min10 l/min
Maximum inlet pressure17 bar15 bar17 bar
Weight19 kg28,5 kg3 kg

Technical data are provided by the manufacturers.

Installation and maintenance

We install the purifier in the argon line of your spectrometer, check the connections for leaks and carry out periodic maintenance. We replace getter tubes, catalysts and molecular sieves when needed, according to each manufacturer’s instructions, so that the argon maintains a constant quality. See also the OES spectrometers we support.

Frequently asked questions

Do I need a purifier if I buy high-purity argon?

Usually yes, especially if you analyse nitrogen or oxygen. The gas in the cylinder may be clean, but impurities enter when cylinders are changed, from regulators and pipework, or from differences between batches. The purifier ensures constant quality where it matters: at the spectrometer inlet.

How often are the purification tubes replaced?

It depends on argon consumption and the quality of the gas entering the purifier. Signs that a replacement is needed are higher nitrogen values, an unstable spark and more frequent repeat analyses. We check the condition of the purifier during maintenance and let you know in good time.

MP-2000 or PD-2012?

The MP-2000 removes all impurities, including moisture. The PD-2012 removes only moisture and CO₂, and is suitable when the argon is of good quality and the problem is moisture.

Do they fit every spectrometer?

Yes. The purifiers are installed in the argon line, between the supply and the spectrometer, and connect to any arc or spark OES spectrometer with the appropriate adapters.

Want to improve the quality of your argon?

Tell us which spectrometer you have and what you analyse, and we will recommend the right solution.

Talk to an engineer →